Service Image

Avionics & Airborne LRUs

Power Supply & Control Panels

Starter Control Panel

Sequenced engine start controller for Kiran Viper II

The Starter Control Panel sequences the starting of the Viper II engine in the Kiran MKI/IA. The Viper engine requires a time-based and RPM-based sequence of auxiliary device activation during start. The panel manages this sequence and includes an engine speed detection circuit for RPM-based cut-out. Sequence: Starter power relay ON at 0s; Igniter and primary burner ON at 4 ±0.5s, OFF at 17 ±0.5s; Rate reset valve ON at 8 ±0.5s, OFF at 25 ±0.5s; Cut-out at 31 ±1.0s or at 25–27% RPM.

KEY DETAILS

• Starts Viper II engine on Kiran MKI/IA • Time-based and RPM-based start sequencing • Engine speed detection for RPM cut-out • Supply 14–29VDC • Starter power relay output: 3.5A at 29VDC • Igniter/primer relay output: 0.5A at 29VDC • Rate reset solenoid output: 0.9A at 29VDC • Input RPM signal 3.5VAC • Dimensions Ø100 × 175 mm, weight ≤ 1600g