Avionics & Airborne LRUs
Fire Warning & Detection Systems
LRU
Fire Detection and Warning System for Light Combat Aircraft
Dual-core loop fire and overheat detection for LCA
The Fire Detection and Warning System is designed for the Light Combat Aircraft to provide reliable detection of overheat and fire conditions. The active element is a continuous dual-core sensing cable; rising temperature produces a signal that is transmitted to a control unit, which activates an alarm when the sensing cable crosses a preset reference value. Sensing cables are joined by interconnecting cables into a loop circuit to protect engine and fuselage sections. A break in any sensing or interconnecting cable does not disable the system — it continues to respond to overheat and fire. The system operates at low resistance and monitors on two lines, producing an ANDed output to avoid false warnings.
KEY DETAILS
• Continuous dual-core sensing cable technology • Loop architecture covering engine and fuselage • Break-tolerant: loop remains operative on single cable break • Two-line monitoring with ANDed output for false-alarm rejection • System Type: SE-FDWS, MK1, MOD1 • Control Unit Part No. SE-FDWS-20 • Sensing cables DRG 20610, 20609 • Non-sensing cables DRG 20606, 20611, 20607